САЖЕТАК / ABSTRACT:
The paper analyzes the influence of electromagnetic fields on workers inside the switchyards. The analysis is based on the results of electric and magnetic field measurements inside several switchyards of different voltage levels. The paper presents the most important provisions of the rulebook related to the area of workers’ exposure to electromagnetic fields. The testing methodology is described and a detailed presentation of the obtained results is given. The testing results are compared with the action levels prescribed by the current rulebook.
КЉУЧНЕ РЕЧИ / KEYWORDS:
electromagnetic field, non-ionizing radiation, electric field, magnetic flux density, switchyard, occupational health and safety
ПРОЈЕКАТ / ACKNOWLEDGEMENT:
Овај рад је подржало Министарство науке, технолошког развоја и иновација Републике Србије кроз Уговор о реализацији и финансирању научноистраживачког рада НИО у 2025. години.
ЛИТЕРАТУРА / REFERENCES:
Извештаји Електротехничког института „Никола Тесла” бр. 324358-Л, 324375-Л, 324401-Л, 324461-Л, 324462-Л, 324474-Л и 324506-Л, наручилац: АД „Електромрежа Србије”, 2024.
SRPS EN 50413: „Основни стандард за процедуре мерења и прорачуна изложености људи електричним, магнетским и електромагнетским пољима (од 0 Hz до 300 GHz)”, 2020.
SRPS EN 62110: „Нивои електричних и магнетских поља која стварају системи за напајање наизменичном струјом – Поступци мерења у погледу опште изложености”, 2011.