ANALIZA GALVANSKIH UTICAJA U OKOLINI UZEMLJIVAČA TRANSFORMATORSKE STANICE U SLUČAJU ZEMLJOSPOJA

37. саветовање CIGRE Србија (2025) СИГУРНОСТ, СТАБИЛНОСТ, ПОУЗДАНОСТ И RESILIENCE ЕЛЕКТРОЕНЕРГЕТСКОГ СИСТЕМА МУЛТИСЕКТОРСКО ПОВЕЗИВАЊЕ У ЕНЕРГЕТИЦИ И ПРИВРЕДИ – B3.05

АУТОР(И) / AUTHOR(S): Stefan Obradović, Maja Grbić, Ranko Jasika, Aleksandar Pavlović

 

Download Full Pdf   

DOI:  10.46793/CIGRE37.B3.05

САЖЕТАК / ABSTRACT:

The paper analyzes the conductive interference of the electrical substation grounding system on a residential building. The building is located within the protective zone of the electrical substation, which creates a risk of excessive conductive interference in the event of a ground fault in the substation. Conductive interference can produce dangerous potentials in the vicinity of the substation, potentially leading to the occurrence of high values of touch and step voltages around the building. Additionally, there is a risk of these potentials being transferred to the building and its low-voltage installation. The paper analyzes these effects and provides an assessment of the risk of exposure to touch and step voltages, as well as an evaluation of the risk for the installations within the building.

КЉУЧНЕ РЕЧИ / KEYWORDS:

conductive interference, grounding system, ground fault, touch voltage, step voltage

ПРОЈЕКАТ / ACKNOWLEDGEMENT:

ЛИТЕРАТУРА / REFERENCES:

  • Pravilnik o tehničkim normativima za uzemljenja elektroenergetskih postrojenja nazivnog napona iznad 1000 V, Sl. list SRJ br. 61/95.
  • IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System, IEEE Standard 81-2012.
  • Maja Grbić, Dragutin Salamon, Aleksandar Pavlović: „Interpretacija rezultata geoelektričnog sondiranja zasnovana na matematičkom modelu dvoslojnog tlaˮ, Zbornik radova, Elektrotehnički institut „Nikola Teslaˮ, Beograd, 2013. godina, knjiga 23, str. 189–198, ISSN 0350-8528, UDK: 621.316.99:537.311.3, DOI: 10.5937/zeint23-4544.
  • SRPS EN 50522:2017 „Uzemljenje energetskih postrojenja naizmeničnog napona preko 1 kV”.
  • Aleksandar Pavlović, Stefan Obradović, Maja Grbić, Ranko Jasika: „Rizik od proboja izolacije električne instalacije niskog napona pri zemljospoju na stubu nadzemnog voda”, 36. savetovanje CIGRE Srbija, Srpski nacionalni komitet Međunarodnog saveta za elektroenergetiku, Zlatibor, Republika Srbija, 22–26. 5. 2023. godine, Zbornik radova, R C4 12, STK C4 – Tehničke performanse EES.