PRIRODNA RADIOAKTIVNOST LUTECIJUMA U PET UREĐAJIMA SA LUTECIJUMSKIM SCINTILACIONIM DETEKTORIMA: UTICAJ NA DIJAGNOSTIČKI REZULTAT, KALIBRACIJU I ŽIVOTNU SREDINU

BEZBEDNOST I ZDRAVLJE NA RADU SA ZDRAVSTVENO-MEDICINSKOG I TEHNIČKOBEZBEDNOSNOG ASPEKTA, EKOLOGIJE I ZAŠTITE OD POŽARA (2025) [206-209]

AUTHOR(S) / АУТОР(И): Vojislav ANTIĆ

Download Full Pdf   

DOI: 10.46793/HSE25.206A

ABSTRACT / САЖЕТАК:

Standardni današnji PET (Pozitronska Emisiona Tomografija) skeneri koriste scintilacione detektore na bazi lutecijuma, u kojima se nalazi i Lu-176 radioizotop. U radu se, na primeru komercijalnog uređaja, ekspicitno proračunao njegov maseni udeo i relevantna radioaktivnost. Analizom dobijenog rezultata, razmatrao se i diskutovao uticaj na klinički rad, kalibracione procedure PET skenera, kao i na bezbednost i zdravlje izloženih radnika, stanovništva i životne sredine, uključujući i period nakon prestanka upotrebe uređaja.

KEYWORDS / КЉУЧНЕ РЕЧИ:

PET uređaji, Lu-176, klinički rad, kalibracija, bezbednost i zdravlje.

REFERENCES / ЛИТЕРАТУРА:

1. Šobić-Šaranović D., Artiko V., Nuklearna medicina, Medicinski fakultet Univerziteta u Beogradu, 2020, ISBN
978-86-7117-623-1.
2. Antic V., Stankovic K. et al. Influence of the scintillation crystal option on the detector response of PET
devices, Nuclear Technology and Radiation Protection, Vol. 29, Iss. 1, pp. 40-45, 2014,
https://doi.org/10.2298/NTRP1401040A
3. Alva-Sánchez, H., Zepeda-Barrios, A., Díaz-Martínez, V.D. et al. Understanding the intrinsic radioactivity
energy spectrum from 176Lu in LYSO/LSO scintillation crystals. Sci Rep 8, 17310, 2018,
https://doi.org/10.1038/s41598-018-35684-x.
4. https://clinicalimagingsystems.com/product/siemens-biograph-40-64-true-point-pet-ct-scanner/
5. Alvarez, P.A., Rodríguez-Villafuerte, M., Martínez-Danchez, A., Alva-Sanchez, H. Background energy spectra
of lutetium-based inorganic scintillators for radiation detection, Nuclear Inst. and Methods in Physics Research
A 1056, 2023, https://doi.org/10.1016/j.nima.2023.168674
208
6. Rogasch J., Hofheinz F. et al. Influences on PET Quantification and Interpretation, Diagnostics, 12(2):451,
2022, doi: 10.3390/diagnostics12020451.
7. Quality Assurance for PET and PET/CT Systems, IAEA Human Health Series no. 1, International Atomic Energy
Agency, Vienna, 2009, ISBN 978–92–0–103609–4.
8. Roberta Matheoud, Ronald Boellaard et al., EFOMP’s protocol quality controls in PET/CT and PET/MR,
Physica Medica 105 2023, https://doi.org/10.1016/j.ejmp.2022.11.010
9. Safety Requirements No. TS-R-1, Regulations for the Safe Transport of Radioactive Material, International
Atomic Energy Agency, Vienna, 2009, ISBN 978–92–0–101909–7.
209