SEISMIC EVALUATION OF EXISTING MULTI-STOREY REINFORCED CONCRETE AND MASONRY BUILDINGS

Geotehnički aspekti građevinarstva i zemljotresno inženjerstvo 2025, Vrnjačka Banja, 15 – 17. oktobar 2025.  (pp. 67-75) 

 

АУТОР(И) / AUTHOR(S): Mustafa Hrasnica

 

Download Full Pdf   

DOI: 10.46793/GEOAG25.067H

САЖЕТАК / ABSTRACT:

The post-World War II reconstruction of Europe includes the extensive construction of large number of multi-story residential buildings. At the beginning, mostly masonry buildings were built, typically with semi-prefabricated floor structures. However, since 1960s, reinforced concrete (RC) structural systems became predominant. The Balkan Peninsula and the former Yugoslavia lie within a seismically active zone of Southeastern Europe, where seismic analysis is a part of everyday structural engineering design. Buildings erected 50 to 70 years ago generally do not comply with contemporary design codes, particularly seismic ones. Their analysis presents a particular challenge for structural engineers due to many unknowns, starting with material properties, construction methods, and often some geometric data. his issue has been discussed using examples of typical multi-story buildings constructed in the city of Sarajevo, Bosnia and Herzegovina, from the mid-1950s to the early 1980s. These include masonry buildings with walls made of solid brick and high-rise buildings with R.C: walls and slabs. Analyses showed that a regular structural system plays a key role in order to achieve good seismic performance.

КЉУЧНЕ РЕЧИ / KEYWORDS:

earthquake, seismic response, existing multi-storey buildings, masonry, R.C. walls

ПРОЈЕКАТ / ACKNOWLEDGEMENT:              

REFERENCES / ЛИТЕРАТУРА:                 

  • Chopra, A.K. (1995): Dynamics of Structures, Prentice Hall, USA.
  • DIANA FEA (2020): DIANA – User´s Manual, Material library. Delft, The Netherlands.
  • EMS-98 (1998): European Macroseismic Scale, Editor G. Grüntal, European Seismological Commission, Luxembourg.
  • Eurocode 2 (EC2) European Standard EN 1992-1 2004. Design of concrete structures Part 1-1: General rules and rules for buildings, CEN European Committee for Standardization, Brussels, EU.
  • Eurocode 8 (EC8) European Standard EN 1998-1 2004. Design of structures for earthquake resistance, Part 1: General rules, seismic actions and rules for buildings, CEN European Committee for Standardization, Brussels, EU.
  • Hrasnica, M. (2012): Aseizmičko građenje (Aseismic buildings). Faculty of Civil Engineering, University of Sarajevo, Bosnia and Herzegovina (in Bosnian).
  • Hrasnica M (2009): Damage Assessment for Masonry and Historic Buildings in Bosnia and Herzegovina. In: Ibrahimbegovic A, Zlatar M (eds) Damage Assessment and Reconstruction after War or Natural Disaster. NATO Science for Peace and Security Series C: Environmental Security, Springer Netherlands, pp. 333-356.
  • Karavelić-Hadžimejlić, A. (2024): Efekat utezanja armiranobetonskih zidova (Effects of confinement by R.C. walls), Report for doctoral studies, University of Sarajevo-Faculty of Civil Engineering, Bosnia and Herzegovina (in Bosnian).
  • Mander, J. B. (1988): Theoretical stress-strain model for confined concrete. Journal of structural engineering, 114(8), 1804-1826.
  • (2018). User´s Manual. Computers and Structures Inc., California, USA.
  • Wilson, E. L. (2002): Three dimensional static and dynamic analysis of structures: a physical approach with emphasis on earthquake engineering. Computers and Structures, Inc., California, USA.