Proceedings of 41st Danubia-Adria Symposium Advances in Experimental Mechanics (pp. 9-10)
АУТОР(И) / AUTHOR(S): Karel Doubrava
, Nikola Schmidová
, David Blaha
, Ctirad Novotný
, Zdenek Padovec
, Radek Sedláček
, Radek Kottner
, Milan Ruzicka 
DOI: 10.46793/41DAS2025.009D
УВОД / INTRODUCTION:
Surface water management is one of the main topics nowadays. The Glass Reinforced Plastic (GRP) surface water treatment tank is one of the important parts of the system chain solution. GRP tanks are placed below the surface, and during the placement process, high loads can occur on the tank structure. The possibility of monitoring loading using sensors is being investigated. Resistive and optical sensors were installed on the surface of the vessel, and verification measurements were performed during the vacuum test of the vessel. The obtained results were compared with the FEM calculation.
КЉУЧНЕ РЕЧИ / KEYWORDS:
ПРОЈЕКАТ / ACKNOWLEDGEMENT:
The work was supported by the project TN02000010 of the National Competence Centre of Mechatronics and Smart Technologies for Mechanical Engineering is co-financed from the state budget by the TACR within the National Centres of Competence Programme.
ЛИТЕРАТУРА / REFERENCES:
- Horoschenkoff, A., Christner, C. Carbon Fibre Sensor: Theory and Application, Composites and Their Applications, Hu, N. ed. InTech, 2012. https://doi.org/10.5772/50504.