OVERVIEW OF PHANTOMS IN DOSIMETRY AND RADIATION PROTECTION

1st International Conference on Chemo and BioInformatics, ICCBIKG  2021, (141-144)

AUTHOR(S) / АУТОР(И): Milena P. Živković, Dragoslav Nikezic, Tatjana B. Miladinović, Dragana Ž. Krstić

E-ADRESS / Е-АДРЕСА: milena.zivkovic@pmf.kg.ac.rs, dragana.krstic@pmf.kg.ac.rs, nikezic@kg.ac.rs, tanja.miladinovic@uni.kg.ac.rs

Download Full Pdf   

DOI: 10.46793/ICCBI21.141Z

ABSTRACT / САЖЕТАК:

In this paper, the characteristics of phantoms from their origin to the latest species are considered. With the development of technique and technology, the characteristics of phantoms have also been improved, whose importance in monitoring human health is extremely important.

The first species were adapted to certain nations and precisely constructed so that sizes such as the height and mass of the phantoms were appropriate and represented the real inhabitants of those areas, that is, the inhabitants of America and Japan.

Later, female, children’s phantoms were formed, as well as phantoms of pregnant women in different stages of pregnancy. The latest generations of phantoms, voxel, and mesh phantoms, represent realistic presentations of the human body and are applied in dosimetry and radiation protection in different areas, as well as in different irradiation conditions.

The International Commission on Radiation Protection – ICRP continuously studies data on radiation doses and effects and issues appropriate protection recommendations and promotes phantoms that represent the human body and organs of great importance for the occurrence of cancer.

KEY WORDS / КЉУЧНЕ РЕЧИ:

radiology, medical physics, male and female phantom, voxels

REFERENCES / ЛИТЕРАТУРА:

  • ICRP, Data for Use in Protection against External ICRP Publication 51. Ann. ICRP 17 (1987).
  • ICRP, Basic Anatomical and Physiological Data for Use in Radiological Protection Reference Values. ICRP Publication 89. Ann. ICRP 32 (2002) 3-4.
  • W. Alderson, L.H. Lanzl, M. Rollins, J. Spira, An instrumented phantom system for analog computation of treatment plans, The American Journal of Roentgenology, 87 (1962) 185.
  • Snyder S., Ford M. R., Warner G. G., Watson G. G., Revision of MIRD Pamphlet No. 5 Entitled Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. ORNL-4979, Oak Ridge National Laboratory, Oak Ridge, Tenn., 1974.
  • Cristy, Mathematical phantoms representing children of various ages for use in estimates of internal dose. U.S. Nuclear Regulatory Commission Rep. NUREG/CR-1159 (also Oak Ridge National Laboratory Rep. ORNL/NUREG/TM-367). 1980.
  • Krstić, D. Nikezić. Input files with ORNL—mathematical phantoms of the human body for MCNP-4B. Computer Physics Communications, 176 (1): 33-37, 2007.
  • Goorley, MCNP Medical Physics Geometry Database. Los Alamos National Laboratory. https://mcnp.lanl.gov/pdf_files/la-ur-07-6618.pdf. 2007.
  • ICRP, Adult reference computational phantoms. ICRP Publication 110. ICRP 39 (2009).
  • ICRP, Adult mesh-type reference computational phantoms. ICRP Publication 145. Ann. ICRP 49 (2020).